A Chisinau apartment where heat-pump consumption is measured separately from the household load.
Adding the second clamp to the IB input of a Pro EM-50 meter to separately measure a dedicated circuit.

This current transformer is a measurement accessory designed exclusively for the Shelly Pro EM-50 and Shelly EM Gen3 energy meters. It is not a standalone device: the clamp supplies the current signal that the meter converts into power and energy readings.<br><br>The split-core design with a ferrite core lets you install the sensor around a live conductor without breaking the circuit, simply by opening the clamp. The transformation ratio is 3000:1, the nominal primary current is 50 A, and the stated accuracy is ±1%. The Ø11 mm inner aperture accepts standard installation conductors.<br><br>The 60 cm cable ends in a 2-pin Molex Micro-Fit connector that plugs directly into the meter's IA or IB inputs. Installation inside the distribution board must be carried out by a qualified electrician.
Adding the second clamp to the IB input of a Pro EM-50 meter to separately measure a dedicated circuit.
Swapping a faulty clamp on an already installed EM Gen3 meter without changing the rest of the wiring.
Measuring the consumption of a dedicated circuit for a rented area with a Pro EM-50 meter.
Same category
Close models and alternatives from the CasaSmart catalog.

Shelly
—

Shelly
—

Shelly
—

Shelly
—

Shelly
—

Shelly
—
Manager guidance
A CasaSmart manager calls you within 1–2 working hours and answers anything — compatibility, install, alternatives.